ESD-suojatut kalusteet 04-2024

Certificate of Qualification Q514/2017 V1.1 15.3.2017 Toni Viheriäkoski Cascade metrology Oy, Hakulintie 32, 08500 Lohja toni.viheriakoski@cascademetrology.com 1/1 Certificate of Qualification Cleanroom Suitability of Treston Concept and WB Workstations The cleanroom suitability of Treston Concept and WB workstations was assessed in the cleanroom of ISO 14644-1 class 7, February 2017. The requirements of ISO class 7 were met at rest and in operation. Summary of the qualification is shown in Table 1. Detailed information is presented in a technical report C514/2017. Table 1: General Information Client Treston Oy, Sorakatu 1, 20730 Turku Contact Kimmo Lehti, +358 50 395 8562, kimmo.lehti@treston.com Dates of Test February 9 – 16, 2017 Place of Test Cascade Metrology, Electrostatics Laboratory, Hakulintie 32, 08500 Lohja GSM +358 4456 88 599 Conditioning ISO Class 7, RH = (25 ± 5) %, T = (23 ± 3) °C Samples under Test Sample 1: Concept motorized ESD workstation 10349015P+TT10060-ESD with accessories, SN 5219, 01/2017 Sample 2: WB811 EL ESD motorized workstation with accessories SN 7154, 01/2017 Test Equipment Particle counter Climet Cl 500 SN 956475, Temperature and humidity meter Vaisala HM 41 SN M1850876, Sensor Vaisala HMP 113 SN M1750872 Assessment Criteria EN ISO 14644-1:2015 Cleanrooms and associated controlled environments - Part 1: Classification of air cleanliness by particle concentration Summary of Results Requirements of ISO class 7 were met at rest and in operation. The requirements of ISO class 6 were also met at rest with the large particle sizes > 0.5 µm. Note This certificate may only be reproduced in full, except with the prior written permission by issuing laboratory. The results relate only to the tested items. Date and place Author Lohja 15.3.2017 Toni Viheriäkoski, CEO, Cascade Metrology, ESD Engineer Certificate of Qualification Q515-1/2017 V1.1 15.3.2017 Toni Viheriäkoski Cascade metrology Oy, Hakulintie 32, 08500 Lohja toni.viheriakoski@cascademetrology.com 1/1 Certificate of Qualification Cleanroom Suitability of Chair Treston Ergo C20PU-ESD The cleanroom suitability of Treston Ergo C20PU-ESD chair was assessed in the cleanroom of ISO 14644-1 class 7, February 2017. The requirements of ISO class 7 were met at rest and in operation. Summary of the qualification is shown in Table 1. Detailed information is presented in a technical report C515/2017. Table 1: General Information Client Treston Oy, Sorakatu 1, 20730 Turku Contact Kimmo Lehti, +358 50 395 8562, kimmo.lehti@treston.com Dates of Test February 26th – March 1st, 2017 Place of Test Cascade Metrology, Electrostatics Laboratory, Hakulintie 32, 08500 Lohja GSM +358 4456 88 599 Conditioning ISO Class 7, RH = (25 ± 5) %, T = (23 ± 3) °C Samples under Test Treston Ergo C20PU-ESD Chair, 20015654, 9651C, 2401978/002, 02.09.2016 Test Equipment Particle counter Climet Cl 500 SN 956475, Temperature and humidity meter Vaisala HM 41 SN M1850876, Sensor Vaisala HMP 113 SN M1750872 Assessment Criteria EN ISO 14644-1:2015 Cleanrooms and associated controlled environments - Part 1: Classification of air cleanliness by particle concentration Summary of Results Requirements of ISO class 7 were met at rest and in operation. The requirements of ISO class 6 were also met at rest with the large particle sizes > 0.5 µm. Note This certificate may only be reproduced in full, except with the prior written permission by issuing laboratory. The results relate only to the tested items. Date and place Author Lohja 15.3.2017 Toni Viheriäkoski, CEO, Cascade Metrology, ESD Engineer Certificate of Qualification Q518/2017 V1.0 18.3.2017 Toni Viheriäkoski Cascade metrology Oy, Hakulintie 32, 08500 Lohja toni.viheriakoski@cascademetrology.com 1/1 Certificate of Qualification ESD control items – Workstations Treston Concept and WB ESD-control characteristics of Treston Concept and WB workstations were assessed in accordance with IEC 61340-5-1 and IEC 61340-2-3. Summary of the qualification is shown in Table 1. Detailed information is presented in a technical report C518/2017. Table 1: General Information Client Treston Oy, Sorakatu 1, 20730 Turku Contact Kimmo Lehti, +358 50 395 8562, kimmo.lehti@treston.com Dates of Test March 12 - 17, 2017 ( C518/2017) Place of Test Cascade Metrology, Electrostatics Laboratory, Hakulintie 32, 08500 Lohja GSM +358 4456 88 599 Conditioning 48 hours, RH = (12 ± 3) %, T = (23 ± 2) °C Samples under Test Sample 1: Concept motorized ESD workstation 10349015P+TT10060-ESD with accessories, SN 5219, 01/2017 Sample 2: WB811 EL ESD motorized workstation with accessories SN 7154, 01/2017 Test Equipment BMM2000ESD Sn /1387, HM41 Sn M1850876, Cylindrical electrode Vermason 222008, Concentric ring electrode Vermason 222002 Test Method(s) IEC 61340-2-3:2016, Edition 2.0, Electrostatics – Part 2-3: Methods of test for determining resistance and resistivity of solid materials used to avoid electrostatic charge accumulation Assessment Criteria IEC 61340-5-1:2016, Edition 2.0, Electrostatics – Part 5-1: Protection of electronic devices from electrostatic phenomena Summary of Results The samples met the requirements of working surfaces according to IEC 61340-5-1. Resistance to groundable point and point to point resistances were below 1 × 109 Ω. Results and observations are presented in a technical report C518/2017. Note This certificate may only be reproduced in full, except with the prior written permission by issuing laboratory. The results relate only to the tested items. Date and place Author Lohja 18.3.2017 Toni Viheriäkoski, CEO, Cascade Metrology, ESD Engineer Place and date: For the issuing office: Espoo, 15 November 2023 DNV - Business Assurance Keilaranta 1, 02150 Espoo, Finland Kimmo Haarala Management Representative Lack of fulfilment of conditions as set out in the Certification Agreement may render this Certificate invalid. ACCREDITED UNIT: DNV Business Assurance Finland Oy Ab, Keilaranta 1, 02150 Espoo, Finland - TEL: +358 10 292 4200. www.dnv.fi/assurance MANAGEMENT SYSTEM CERTIFICATE Certificate no.: C597451 Initial certification date: 15 November 2023 Valid: 15 November 2023 – 14 November 2026 This is to certify that the management system of Treston Oy Sorakatu 1, 20730 Turku, Finland and the sites as mentioned in the appendix accompanying this certificate has been found to conform to the Quality Management System standard: ISO 9001:2015 This certificate is valid for the following scope: Design, production, sales and marketing of workstations and material handling systems for industry and other technical environments and storage systems. 11 Treston - ESD-suojatut kalusteet Normimme ovat tiukimpien sertifiointivaatimusten mukaiset Laatusertifikaatti ISO 9001 : 2015 ESD-hyväksynnän sertifikaatti ESD-tuotteemme täyttävät standardin IEC 613405-1 mukaiset perusvaatimukset. Puhdastilasertifikaatti Treston WB- ja Concept -työpisteiden soveltuvuudesta ISO 14644-1 mukaisesti puhdastilaluokkaan 7. Puhdastilasertifikaatti Treston Ergo C20PU-ESD -tuolin soveltuvuudesta ISO 14644-1 mukaisesti puhdastilaluokkaan 7. ESD-sertifikaatti Treston WB- ja Concept-työpisteet täyttävät standardin IEC 61340-5-1 vaatimukset. ESD-sertifikaatti Trestonin hylly-, otto, säilytys ja poimintalaatikot sekä hyllylaatikostot täyttävät standardin IEC61340-5-1 vaatimukset. Voit tilata jäljennökset sertifikaateistamme osoitteesta info@treston.com. Treston™ tuotteille myönnetään 10 vuoden takuu toimituspäivästä lukien, tietyin poikkeuksin. Muovilaatikoiden takuuaika on 5 vuotta. Pöytätasojen, sähkökomponenttien, satulatuolien, valaisimien sekä kuluvien osien kuten pyörien, liukupalojen ja -kiskojen ja rullaprofiilien takuuaika on 2 vuotta. Välitystuotteille ja -komponenteille sekä asiakaskohtaisesti valmistetuille tuotteille myönnämme 2 vuoden takuun, ellei toisin sovita. TRESTON TAKUUAIKA �10 VUOTTA� 10 YEAR GUARANTEE 10 YEAR GUARANTEE

RkJQdWJsaXNoZXIy NDk0Mw==